Objective: To evaluate early and mid-term outcomes of thoracic endovascular aortic repair (TEVAR) using the Castor single-branched aortic stent graft in a real-world multicenter Italian experience. Methods: This retrospective, nonrandomized, multicenter study included all consecutive patients treated with the Castor stent graft between January 2019 and April 2025 in eight Italian centers. The device was used in patients with thoracic aortic pathologies requiring TEVAR in proximal landing zones 1 or 2. Primary endpoints included technical success, intraoperative major adverse events (MAEs), and deployment accuracy. Secondary endpoints were aortic-related mortality, neurological complications, reinterventions, and endoleaks. Results: Fifty-one patients (mean age 68.8 ± 8 years, 75.5% male) were treated, primarily for type B aortic dissection (45.1%) and thoracic aortic aneurysm (27.5%). Proximal landing was in zone 2 in 92.1% and zone 1 in 7.8% of cases. The technical success rate was 94.1%, with three cases (5.8%) of intraoperative type Ia endoleak. No intraoperative deaths or major adverse events occurred. Two cases of minor embolic stroke (3.9%) were observed, both in zone 1 procedures involving left common carotid artery revascularization. At a median follow-up of 22.3 months (range 2–58), no additional endoleaks or neurological events were reported, with 100% branch patency rate. Conclusions: The Castor single-branched stent graft is a feasible option for TEVAR in zone 2, with high technical success and low rates of neurological complications. Accurate case selection and procedural planning are essential.

Proximal Sealing in Zone 1–2 Using the Castor Stent-Graft: Early Results from an Italian Multicenter Registry

Rizza, Antonio;Tinelli, Giovanni;Trimarchi, Giancarlo;Foffa, Ilenia;Bastiani, Luca;Di Sibio, Silvia;Murzi, Michele;Palmieri, Cataldo;Tusini, Nicola;Colli, Andrea;Berti, Sergio;
2026-01-01

Abstract

Objective: To evaluate early and mid-term outcomes of thoracic endovascular aortic repair (TEVAR) using the Castor single-branched aortic stent graft in a real-world multicenter Italian experience. Methods: This retrospective, nonrandomized, multicenter study included all consecutive patients treated with the Castor stent graft between January 2019 and April 2025 in eight Italian centers. The device was used in patients with thoracic aortic pathologies requiring TEVAR in proximal landing zones 1 or 2. Primary endpoints included technical success, intraoperative major adverse events (MAEs), and deployment accuracy. Secondary endpoints were aortic-related mortality, neurological complications, reinterventions, and endoleaks. Results: Fifty-one patients (mean age 68.8 ± 8 years, 75.5% male) were treated, primarily for type B aortic dissection (45.1%) and thoracic aortic aneurysm (27.5%). Proximal landing was in zone 2 in 92.1% and zone 1 in 7.8% of cases. The technical success rate was 94.1%, with three cases (5.8%) of intraoperative type Ia endoleak. No intraoperative deaths or major adverse events occurred. Two cases of minor embolic stroke (3.9%) were observed, both in zone 1 procedures involving left common carotid artery revascularization. At a median follow-up of 22.3 months (range 2–58), no additional endoleaks or neurological events were reported, with 100% branch patency rate. Conclusions: The Castor single-branched stent graft is a feasible option for TEVAR in zone 2, with high technical success and low rates of neurological complications. Accurate case selection and procedural planning are essential.
2026
File in questo prodotto:
File Dimensione Formato  
48. Proximal Sealing in Zone 1–2 Using the Castor Stent-Graft Early Results from an Italian Multicenter Registry.pdf

accesso aperto

Tipologia: Documento in Pre-print/Submitted manuscript
Licenza: Creative commons (selezionare)
Dimensione 1.16 MB
Formato Adobe PDF
1.16 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/590496
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
social impact