Conventional gel electrodes are the gold standard for surface electromyography (sEMG), yet their bulkiness, stiffness, and limited gel lifetime prevents seamless day-long integration with wearable robots. We integrated ultrathin skin-conformal temporary tattoo electrodes with a powered unilateral hip exoskeleton and compared signal quality during treadmill walking against gel. In this pilot study, five healthy participants completed three consecutive walking blocks at fixed speed: (1) using gel electrodes; (2) using tattoo electrodes to compare signal quality; and (3) using the same tattoo electrodes (not repositioned) after eight hours of wear to simulate a full day of typical device use and to evaluate potential degradation in signal quality over time. Electrodes were positioned on muscles not covered by the exoskeleton interface (tibialis anterior and gastrocnemius medialis), as well as on muscles located beneath the exoskeleton cuff, which were potentially subject to motion artifacts due to the application of external forces by the exoskeleton (rectus femoris and biceps femoris, BF). Across all muscles, for both gel and tattoo electrodes, the root mean square error (RMSE) between normalized sEMG envelopes and biological activation profile was 0.069 ± 0.048, and Pearson’s correlation coefficient (ρ) was 0.844 ± 0.091. Re-testing the same tattoo electrode pair after eight hours confirmed day-long stability without the need for recalibration. Statistical analysis revealed no significant differences in signal quality, also when applying assistive forces, between the two electrode types and across all muscles (RMSE, all p ≥ 0.3125; ρ, all p ≥ 0.1250), as well as no degradation after eight hours (RMSE and ρ: all p ≥ 0.0626, uncorrected). Finally, in a proof-of-concept session, BF activity measured with tattoo electrodes was found reliable to drive hip-extension assistance in real time. Collectively, these results show that tattoo electrodes deliver signal quality comparable to gel electrodes while offering a low-profile skin-conformal interface and day-long usability, making them a promising option for enhancing EMG-based control in wearable robots.

Ultrathin Temporary Tattoo Electrodes Enable Prolonged Skin-Conformable EMG Sensing for Hip Exoskeleton Control

Foggetti, Michele;Galliani, Marina;Pergolini, Andrea;Poliziani, Aliria;Trigili, Emilio;Greco, Francesco;Vitiello, Nicola;Ferrari, Laura M.
;
Crea, Simona
2026-01-01

Abstract

Conventional gel electrodes are the gold standard for surface electromyography (sEMG), yet their bulkiness, stiffness, and limited gel lifetime prevents seamless day-long integration with wearable robots. We integrated ultrathin skin-conformal temporary tattoo electrodes with a powered unilateral hip exoskeleton and compared signal quality during treadmill walking against gel. In this pilot study, five healthy participants completed three consecutive walking blocks at fixed speed: (1) using gel electrodes; (2) using tattoo electrodes to compare signal quality; and (3) using the same tattoo electrodes (not repositioned) after eight hours of wear to simulate a full day of typical device use and to evaluate potential degradation in signal quality over time. Electrodes were positioned on muscles not covered by the exoskeleton interface (tibialis anterior and gastrocnemius medialis), as well as on muscles located beneath the exoskeleton cuff, which were potentially subject to motion artifacts due to the application of external forces by the exoskeleton (rectus femoris and biceps femoris, BF). Across all muscles, for both gel and tattoo electrodes, the root mean square error (RMSE) between normalized sEMG envelopes and biological activation profile was 0.069 ± 0.048, and Pearson’s correlation coefficient (ρ) was 0.844 ± 0.091. Re-testing the same tattoo electrode pair after eight hours confirmed day-long stability without the need for recalibration. Statistical analysis revealed no significant differences in signal quality, also when applying assistive forces, between the two electrode types and across all muscles (RMSE, all p ≥ 0.3125; ρ, all p ≥ 0.1250), as well as no degradation after eight hours (RMSE and ρ: all p ≥ 0.0626, uncorrected). Finally, in a proof-of-concept session, BF activity measured with tattoo electrodes was found reliable to drive hip-extension assistance in real time. Collectively, these results show that tattoo electrodes deliver signal quality comparable to gel electrodes while offering a low-profile skin-conformal interface and day-long usability, making them a promising option for enhancing EMG-based control in wearable robots.
2026
File in questo prodotto:
File Dimensione Formato  
sensors-26-02587-v2.pdf

accesso aperto

Tipologia: PDF Editoriale
Licenza: Creative commons (selezionare)
Dimensione 3.24 MB
Formato Adobe PDF
3.24 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/588092
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
social impact